2027 observing campaignThe call for the 2026 observing campaign is not yet open! THEMIS 2027 observing campaign will take place approximately from mid-April to mid-November, 2027, lasting for about XXX days. 2027 campaign scheduleThe 2027 campaign shall observe the following schedule:
Call for observation time during the 2027 campaign (not yet open)
Interested researchers are encouraged to check the available instrumentation for 2027, the information on THEMIS observing capacities, as well as the available data products. Inquiries : Applicants, in particular if they are not familiar with THEMIS observations, are encouraged to contact the THEMIS staff — in particular email themis.team@themis.iac.es —- directly to obtain more specific information or express their needs. Given the smaller amount of international time, interested international researchers can also contact the THEMIS staff to discuss possible joint campaign with French applicants, in case compatible observation targets/mode are envisioned. How to applyThe submission of proposals is specific to the instrument (MTR2 or IBIS 2.0) and the category of users one belongs, based on rules of access. As soon as the appropriate proposal refereeing procedures of each community and TAC have been passed, applicants shall quickly be informed of their application outcomes. Distinct proposals shall be made for the MTR2 and IBIS 2.0 instruments MTR2 spectrograph
IBIS 2.0
|
![]() |
TAO is available and tested over sunspots and granulation with good results over significantly long periods of time (seeing dependent).
In 2027, IBIS 2.0 & MTR2 instruments cannot be used simultaneously nor sequentially. Time allocation for each instrument will granted during distinct periods of the year. Separated proposals must be submitted by observers who which to use both instruments during the year.
In this mode, up to 4 (new) Andor Zyla cameras up to 4 (old) EMCCD Andor iXon camera. Because of informatics and optical elements constraints, a maximum of 5 cameras can be setup and used simultaneously (with their respective specification), in accordance with the MTR2 spectrograph output physical limitations.
THEMIS polarimetric analysis scheme is based on a full-Stokes analyzer located at the F1 prime focus. For any solar polarization state to measure, the output of the analyzer is made of dual superimposed complementary linear polarizations. Thanks to THEMIS “polarization friendly” new optical scheme, this output travels through the telescope and arrives unperturbed on the spectrograph cameras (cf. information about MTR2 spectrograph). Just in front of the camera, a Wollaston splitter separates the beam into complementary Stokes components to form the spectral focal plane. THEMIS own three Wollaston, hence 3 cameras/3 wavebands at most can be simultaneously observed with polarimetric signal, among the 6 spectral cameras that THEMIS proposes. It is however possible to combine polarimetric and non-polarimetric cameras.
THEMIS BBI fast camera (40 frames/s), is running concurrently with the spectrograph. Current setup is for the continuum around 656 nm (red), but can be optionally changed to G-band or other.
© 2026 CNRS-THEMIS
Terms of use: unless otherwise specified, all graphical (webcam records, movies, pictures) or non-graphical material (text) from this site is property of CNRS-THEMIS under a Creative Commons CC-BY 4.0 license.